﻿<?xml version="1.0" encoding="UTF-8" ?>
<ROOT>
<Infomation PARAM="/TYPE:0/VER:6.0/REV:6/FILE:1">
Roboticsware, Inc. PA-Panel6 Server6.0 Rev6 Created 2018/01/10 10:58:36
</Infomation>
<Common PARAM="+ROOTFOLDER=..+KEEPPROCESS=Y+SYSTEMFOLDER=server_data+SYSTEMFOLDERSUB=X:\server_data+ENABLESYSTEMFOLDER=Y+ENABLERESOURCECHECKER=Y+RESOURCECHECKERFOLDER=server_data\log\systemlog+DISPLAYSTATEMODE=NONE+DISPLAYSTATEFILE=view_baserver60.txt">
</Common>
<Tag PARAM="">
<Driver PARAM="">
<I>"SYS#VIRTUAL.SPECIAL:0,N,,+NOVIRTUALWHENONLINEDEBUG=Y","ALM#+SCAN=1000","ALL#B:"</I>
<I>"*","*","ALL_NOTACK#B:"</I>
<I>"*","*","ALL_NOTRECOVER#B:"</I>
<I>"*","*","ALL_NOTACK_OR_NOTRECOVER#B:"</I>
<I>"*","*","HEAVY#B:"</I>
<I>"*","*","HEAVY_NOTACK#B:"</I>
<I>"*","*","HEAVY_NOTRECOVER#B:"</I>
<I>"*","*","HEAVY_NOTACK_OR_NOTRECOVER#B:"</I>
<I>"*","*","LIGHT#B:"</I>
<I>"*","*","LIGHT_NOTACK#B:"</I>
<I>"*","*","LIGHT_NOTRECOVER#B:"</I>
<I>"*","*","LIGHT_NOTACK_OR_NOTRECOVER#B:"</I>
<I>"*","*","BUZZER_RESET#PULSE:3000"</I>
<I>"*","REPORT#","PRINTDAY#DB:-1,-1,-1,8,0,0,N,0,;-1,-1,-1,8,0,5,N,0,"</I>
<I>"*","*","PRINTMONTH#DB:-1,-1,1,8,10,0,N,0,;-1,-1,1,8,10,5,N,0,"</I>
<I>"*","*","PRINTYEAR#DB:-1,1,1,8,20,0,N,0,;-1,1,1,8,20,5,N,0,"</I>
<I>"*","MODE#+SCAN=1000","PLC01_VIRTUAL#B:N,1"</I>
<I>"DISK#VIRTUAL.SPECIAL:2,N,server_data\system\tag\disktag,X:\server_data\system\tag\disktag+NOVIRTUALWHENONLINEDEBUG=Y","ALM#","DMYNUM_0#N:N,1"</I>
<I>"*","*","DMYNUM_1#N:N,1"</I>
<I>"PLC01#MIT.QQ.E:,8192,192.168.1.221,5000,UDP,0,3000,N;Y,0,Y,YY,10+VIRTUAL=Y","F01#00,FF,03FF","SIM_MODE#M00400"</I>
<I>"*","*","M02001#M02001"</I>
<I>"*","*","M02002#M02002"</I>
<I>"*","*","M02003#M02003"</I>
<I>"*","*","M02011#M02011"</I>
<I>"*","*","M02012#M02012"</I>
<I>"*","*","M02013#M02013"</I>
<I>"*","*","M02021#M02021"</I>
<I>"*","*","M02022#M02022"</I>
<I>"*","*","M02023#M02023"</I>
<I>"*","*","M02031#M02031"</I>
<I>"*","*","M02032#M02032"</I>
<I>"*","*","M02033#M02033"</I>
<I>"*","*","M02041#M02041"</I>
<I>"*","*","M02042#M02042"</I>
<I>"*","*","M02043#M02043"</I>
<I>"*","*","M02051#M02051"</I>
<I>"*","*","M02052#M02052"</I>
<I>"*","*","M02053#M02053"</I>
<I>"*","*","M02061#M02061"</I>
<I>"*","*","M02062#M02062"</I>
<I>"*","*","M02063#M02063"</I>
<I>"*","*","M02071#M02071"</I>
<I>"*","*","M02072#M02072"</I>
<I>"*","*","M02073#M02073"</I>
<I>"*","*","M02081#M02081"</I>
<I>"*","*","M02082#M02082"</I>
<I>"*","*","M02083#M02083"</I>
<I>"*","*","M02091#M02091"</I>
<I>"*","*","M02092#M02092"</I>
<I>"*","*","M02093#M02093"</I>
<I>"*","*","ZZR03001#ZZR03001"</I>
<I>"*","*","ZZR03002#ZZR03002"</I>
<I>"*","*","ZZR03009#ZZR03009"</I>
<I>"*","*","ZZR03010@0.BIN1#ZZR03010@0.BIN1"</I>
<I>"*","*","ZZR03010@2.BIN1#ZZR03010@2.BIN1"</I>
<I>"*","*","ZZR03009@0.BIN1#ZZR03009@0.BIN1"</I>
<I>"*","*","ZZR03009@2.BIN1#ZZR03009@2.BIN1"</I>
<I>"*","*","ZZR03006#ZZR03006"</I>
<I>"*","*","ZZR03009@5.BIN1#ZZR03009@5.BIN1"</I>
<I>"*","*","ZZR03000#ZZR03000"</I>
<I>"*","*","ZZR03003@0.BIN1#ZZR03003@0.BIN1"</I>
<I>"*","*","ZZR03003@1.BIN1#ZZR03003@1.BIN1"</I>
<I>"*","*","ZZR03131#ZZR03131"</I>
<I>"*","*","ZZR03132#ZZR03132"</I>
<I>"*","*","ZZR03139#ZZR03139"</I>
<I>"*","*","ZZR03140@0.BIN1#ZZR03140@0.BIN1"</I>
<I>"*","*","ZZR03140@2.BIN1#ZZR03140@2.BIN1"</I>
<I>"*","*","ZZR03139@0.BIN1#ZZR03139@0.BIN1"</I>
<I>"*","*","ZZR03139@2.BIN1#ZZR03139@2.BIN1"</I>
<I>"*","*","ZZR03136#ZZR03136"</I>
<I>"*","*","ZZR03139@5.BIN1#ZZR03139@5.BIN1"</I>
<I>"*","*","ZZR03130#ZZR03130"</I>
<I>"*","*","ZZR03133@0.BIN1#ZZR03133@0.BIN1"</I>
<I>"*","*","ZZR03133@1.BIN1#ZZR03133@1.BIN1"</I>
<I>"*","*","ZZR03261#ZZR03261"</I>
<I>"*","*","ZZR03262#ZZR03262"</I>
<I>"*","*","ZZR03269#ZZR03269"</I>
<I>"*","*","ZZR03270@0.BIN1#ZZR03270@0.BIN1"</I>
<I>"*","*","ZZR03270@2.BIN1#ZZR03270@2.BIN1"</I>
<I>"*","*","ZZR03269@0.BIN1#ZZR03269@0.BIN1"</I>
<I>"*","*","ZZR03269@2.BIN1#ZZR03269@2.BIN1"</I>
<I>"*","*","ZZR03266#ZZR03266"</I>
<I>"*","*","ZZR03269@5.BIN1#ZZR03269@5.BIN1"</I>
<I>"*","*","ZZR03260#ZZR03260"</I>
<I>"*","*","ZZR03263@0.BIN1#ZZR03263@0.BIN1"</I>
<I>"*","*","ZZR03263@1.BIN1#ZZR03263@1.BIN1"</I>
<I>"*","*","ZZR03391#ZZR03391"</I>
<I>"*","*","ZZR03392#ZZR03392"</I>
<I>"*","*","ZZR03399#ZZR03399"</I>
<I>"*","*","ZZR03400@0.BIN1#ZZR03400@0.BIN1"</I>
<I>"*","*","ZZR03400@2.BIN1#ZZR03400@2.BIN1"</I>
<I>"*","*","ZZR03399@0.BIN1#ZZR03399@0.BIN1"</I>
<I>"*","*","ZZR03399@2.BIN1#ZZR03399@2.BIN1"</I>
<I>"*","*","ZZR03396#ZZR03396"</I>
<I>"*","*","ZZR03399@5.BIN1#ZZR03399@5.BIN1"</I>
<I>"*","*","ZZR03390#ZZR03390"</I>
<I>"*","*","ZZR03393@0.BIN1#ZZR03393@0.BIN1"</I>
<I>"*","*","ZZR03393@1.BIN1#ZZR03393@1.BIN1"</I>
<I>"*","*","ZZR03521#ZZR03521"</I>
<I>"*","*","ZZR03522#ZZR03522"</I>
<I>"*","*","ZZR03529#ZZR03529"</I>
<I>"*","*","ZZR03530@0.BIN1#ZZR03530@0.BIN1"</I>
<I>"*","*","ZZR03530@2.BIN1#ZZR03530@2.BIN1"</I>
<I>"*","*","ZZR03529@0.BIN1#ZZR03529@0.BIN1"</I>
<I>"*","*","ZZR03529@2.BIN1#ZZR03529@2.BIN1"</I>
<I>"*","*","ZZR03526#ZZR03526"</I>
<I>"*","*","ZZR03529@5.BIN1#ZZR03529@5.BIN1"</I>
<I>"*","*","ZZR03520#ZZR03520"</I>
<I>"*","*","ZZR03523@0.BIN1#ZZR03523@0.BIN1"</I>
<I>"*","*","ZZR03523@1.BIN1#ZZR03523@1.BIN1"</I>
<I>"*","*","ZZR07551#ZZR07551"</I>
<I>"*","*","ZZR07552#ZZR07552"</I>
<I>"*","*","ZZR07559#ZZR07559"</I>
<I>"*","*","ZZR07560@0.BIN1#ZZR07560@0.BIN1"</I>
<I>"*","*","ZZR07560@2.BIN1#ZZR07560@2.BIN1"</I>
<I>"*","*","ZZR07559@0.BIN1#ZZR07559@0.BIN1"</I>
<I>"*","*","ZZR07559@2.BIN1#ZZR07559@2.BIN1"</I>
<I>"*","*","ZZR07556#ZZR07556"</I>
<I>"*","*","ZZR07559@5.BIN1#ZZR07559@5.BIN1"</I>
<I>"*","*","ZZR07550#ZZR07550"</I>
<I>"*","*","ZZR07553@0.BIN1#ZZR07553@0.BIN1"</I>
<I>"*","*","ZZR07553@1.BIN1#ZZR07553@1.BIN1"</I>
<I>"*","*","ZZR07681#ZZR07681"</I>
<I>"*","*","ZZR07682#ZZR07682"</I>
<I>"*","*","ZZR07689#ZZR07689"</I>
<I>"*","*","ZZR07690@0.BIN1#ZZR07690@0.BIN1"</I>
<I>"*","*","ZZR07690@2.BIN1#ZZR07690@2.BIN1"</I>
<I>"*","*","ZZR07689@0.BIN1#ZZR07689@0.BIN1"</I>
<I>"*","*","ZZR07689@2.BIN1#ZZR07689@2.BIN1"</I>
<I>"*","*","ZZR07686#ZZR07686"</I>
<I>"*","*","ZZR07689@5.BIN1#ZZR07689@5.BIN1"</I>
<I>"*","*","ZZR07680#ZZR07680"</I>
<I>"*","*","ZZR07683@0.BIN1#ZZR07683@0.BIN1"</I>
<I>"*","*","ZZR07683@1.BIN1#ZZR07683@1.BIN1"</I>
<I>"*","*","ZZR03660#ZZR03660.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03672#ZZR03672.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03674#ZZR03674.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03656#ZZR03656"</I>
<I>"*","*","ZZR03650#ZZR03650"</I>
<I>"*","*","ZZR03690#ZZR03690.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03653@8.BIN1#ZZR03653@8.BIN1"</I>
<I>"*","*","ZZR03653@6.BIN1#ZZR03653@6.BIN1"</I>
<I>"*","*","ZZR03653@5.BIN1#ZZR03653@5.BIN1"</I>
<I>"*","*","ZZR03653@7.BIN1#ZZR03653@7.BIN1"</I>
<I>"*","*","ZZR03680#ZZR03680.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03676#ZZR03676.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03678#ZZR03678.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03682#ZZR03682.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03790#ZZR03790.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03802#ZZR03802.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03804#ZZR03804.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03786#ZZR03786"</I>
<I>"*","*","ZZR03780#ZZR03780"</I>
<I>"*","*","ZZR03820#ZZR03820.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03783@8.BIN1#ZZR03783@8.BIN1"</I>
<I>"*","*","ZZR03783@6.BIN1#ZZR03783@6.BIN1"</I>
<I>"*","*","ZZR03783@5.BIN1#ZZR03783@5.BIN1"</I>
<I>"*","*","ZZR03783@7.BIN1#ZZR03783@7.BIN1"</I>
<I>"*","*","ZZR03810#ZZR03810.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03806#ZZR03806.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03808#ZZR03808.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03812#ZZR03812.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03920#ZZR03920.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03932#ZZR03932.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03934#ZZR03934.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03916#ZZR03916"</I>
<I>"*","*","ZZR03910#ZZR03910"</I>
<I>"*","*","ZZR03950#ZZR03950.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03913@8.BIN1#ZZR03913@8.BIN1"</I>
<I>"*","*","ZZR03913@6.BIN1#ZZR03913@6.BIN1"</I>
<I>"*","*","ZZR03913@5.BIN1#ZZR03913@5.BIN1"</I>
<I>"*","*","ZZR03913@7.BIN1#ZZR03913@7.BIN1"</I>
<I>"*","*","ZZR03940#ZZR03940.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03936#ZZR03936.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03938#ZZR03938.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR03942#ZZR03942.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04050#ZZR04050.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04062#ZZR04062.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04064#ZZR04064.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04046#ZZR04046"</I>
<I>"*","*","ZZR04040#ZZR04040"</I>
<I>"*","*","ZZR04080#ZZR04080.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04043@8.BIN1#ZZR04043@8.BIN1"</I>
<I>"*","*","ZZR04043@6.BIN1#ZZR04043@6.BIN1"</I>
<I>"*","*","ZZR04043@5.BIN1#ZZR04043@5.BIN1"</I>
<I>"*","*","ZZR04043@7.BIN1#ZZR04043@7.BIN1"</I>
<I>"*","*","ZZR04070#ZZR04070.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04066#ZZR04066.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04068#ZZR04068.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04072#ZZR04072.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04180#ZZR04180.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04192#ZZR04192.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04194#ZZR04194.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04176#ZZR04176"</I>
<I>"*","*","ZZR04170#ZZR04170"</I>
<I>"*","*","ZZR04210#ZZR04210.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04173@8.BIN1#ZZR04173@8.BIN1"</I>
<I>"*","*","ZZR04173@6.BIN1#ZZR04173@6.BIN1"</I>
<I>"*","*","ZZR04173@5.BIN1#ZZR04173@5.BIN1"</I>
<I>"*","*","ZZR04173@7.BIN1#ZZR04173@7.BIN1"</I>
<I>"*","*","ZZR04200#ZZR04200.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04196#ZZR04196.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04198#ZZR04198.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04202#ZZR04202.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07820#ZZR07820.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07832#ZZR07832.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07834#ZZR07834.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07816#ZZR07816"</I>
<I>"*","*","ZZR07810#ZZR07810"</I>
<I>"*","*","ZZR07850#ZZR07850.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07813@8.BIN1#ZZR07813@8.BIN1"</I>
<I>"*","*","ZZR07813@6.BIN1#ZZR07813@6.BIN1"</I>
<I>"*","*","ZZR07813@5.BIN1#ZZR07813@5.BIN1"</I>
<I>"*","*","ZZR07813@7.BIN1#ZZR07813@7.BIN1"</I>
<I>"*","*","ZZR07840#ZZR07840.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07836#ZZR07836.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07838#ZZR07838.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07842#ZZR07842.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07950#ZZR07950.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07962#ZZR07962.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07964#ZZR07964.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07946#ZZR07946"</I>
<I>"*","*","ZZR07940#ZZR07940"</I>
<I>"*","*","ZZR07980#ZZR07980.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07943@8.BIN1#ZZR07943@8.BIN1"</I>
<I>"*","*","ZZR07943@6.BIN1#ZZR07943@6.BIN1"</I>
<I>"*","*","ZZR07943@5.BIN1#ZZR07943@5.BIN1"</I>
<I>"*","*","ZZR07943@7.BIN1#ZZR07943@7.BIN1"</I>
<I>"*","*","ZZR07970#ZZR07970.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07966#ZZR07966.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07968#ZZR07968.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07972#ZZR07972.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08080#ZZR08080.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08092#ZZR08092.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08094#ZZR08094.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08076#ZZR08076"</I>
<I>"*","*","ZZR08070#ZZR08070"</I>
<I>"*","*","ZZR08110#ZZR08110.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08073@8.BIN1#ZZR08073@8.BIN1"</I>
<I>"*","*","ZZR08073@6.BIN1#ZZR08073@6.BIN1"</I>
<I>"*","*","ZZR08073@5.BIN1#ZZR08073@5.BIN1"</I>
<I>"*","*","ZZR08073@7.BIN1#ZZR08073@7.BIN1"</I>
<I>"*","*","ZZR08100#ZZR08100.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08096#ZZR08096.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08098#ZZR08098.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08102#ZZR08102.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08210#ZZR08210.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08222#ZZR08222.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08224#ZZR08224.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08206#ZZR08206"</I>
<I>"*","*","ZZR08200#ZZR08200"</I>
<I>"*","*","ZZR08240#ZZR08240.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08203@8.BIN1#ZZR08203@8.BIN1"</I>
<I>"*","*","ZZR08203@6.BIN1#ZZR08203@6.BIN1"</I>
<I>"*","*","ZZR08203@5.BIN1#ZZR08203@5.BIN1"</I>
<I>"*","*","ZZR08203@7.BIN1#ZZR08203@7.BIN1"</I>
<I>"*","*","ZZR08230#ZZR08230.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08226#ZZR08226.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08228#ZZR08228.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08232#ZZR08232.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04301#ZZR04301"</I>
<I>"*","*","ZZR04302#ZZR04302"</I>
<I>"*","*","ZZR04394#ZZR04394"</I>
<I>"*","*","ZZR04310#ZZR04310.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04314#ZZR04314.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04390#ZZR04390.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04316#ZZR04316.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04334#ZZR04334.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04336#ZZR04336.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04322#ZZR04322.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04324#ZZR04324.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04306#ZZR04306"</I>
<I>"*","*","ZZR04300#ZZR04300"</I>
<I>"*","*","ZZR04340#ZZR04340.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04303@8.BIN1#ZZR04303@8.BIN1"</I>
<I>"*","*","ZZR04303@6.BIN1#ZZR04303@6.BIN1"</I>
<I>"*","*","ZZR04303@5.BIN1#ZZR04303@5.BIN1"</I>
<I>"*","*","ZZR04303@7.BIN1#ZZR04303@7.BIN1"</I>
<I>"*","*","ZZR04330#ZZR04330.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04326#ZZR04326.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04328#ZZR04328.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04332#ZZR04332.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04303@2.BIN1#ZZR04303@2.BIN1"</I>
<I>"*","*","ZZR04350#ZZR04350.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04431#ZZR04431"</I>
<I>"*","*","ZZR04432#ZZR04432"</I>
<I>"*","*","ZZR04524#ZZR04524"</I>
<I>"*","*","ZZR04440#ZZR04440.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04444#ZZR04444.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04520#ZZR04520.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04446#ZZR04446.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04464#ZZR04464.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04466#ZZR04466.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04452#ZZR04452.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04454#ZZR04454.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04436#ZZR04436"</I>
<I>"*","*","ZZR04430#ZZR04430"</I>
<I>"*","*","ZZR04470#ZZR04470.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04433@8.BIN1#ZZR04433@8.BIN1"</I>
<I>"*","*","ZZR04433@6.BIN1#ZZR04433@6.BIN1"</I>
<I>"*","*","ZZR04433@5.BIN1#ZZR04433@5.BIN1"</I>
<I>"*","*","ZZR04433@7.BIN1#ZZR04433@7.BIN1"</I>
<I>"*","*","ZZR04460#ZZR04460.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04456#ZZR04456.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04458#ZZR04458.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04462#ZZR04462.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04433@2.BIN1#ZZR04433@2.BIN1"</I>
<I>"*","*","ZZR04480#ZZR04480.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04561#ZZR04561"</I>
<I>"*","*","ZZR04562#ZZR04562"</I>
<I>"*","*","ZZR04654#ZZR04654"</I>
<I>"*","*","ZZR04570#ZZR04570.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04574#ZZR04574.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04650#ZZR04650.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04576#ZZR04576.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04594#ZZR04594.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04596#ZZR04596.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04582#ZZR04582.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04584#ZZR04584.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04566#ZZR04566"</I>
<I>"*","*","ZZR04560#ZZR04560"</I>
<I>"*","*","ZZR04600#ZZR04600.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04563@8.BIN1#ZZR04563@8.BIN1"</I>
<I>"*","*","ZZR04563@6.BIN1#ZZR04563@6.BIN1"</I>
<I>"*","*","ZZR04563@5.BIN1#ZZR04563@5.BIN1"</I>
<I>"*","*","ZZR04563@7.BIN1#ZZR04563@7.BIN1"</I>
<I>"*","*","ZZR04590#ZZR04590.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04586#ZZR04586.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04588#ZZR04588.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04592#ZZR04592.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04563@2.BIN1#ZZR04563@2.BIN1"</I>
<I>"*","*","ZZR04610#ZZR04610.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04691#ZZR04691"</I>
<I>"*","*","ZZR04692#ZZR04692"</I>
<I>"*","*","ZZR04784#ZZR04784"</I>
<I>"*","*","ZZR04700#ZZR04700.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04704#ZZR04704.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04780#ZZR04780.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04706#ZZR04706.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04724#ZZR04724.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04726#ZZR04726.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04712#ZZR04712.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04714#ZZR04714.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04696#ZZR04696"</I>
<I>"*","*","ZZR04690#ZZR04690"</I>
<I>"*","*","ZZR04730#ZZR04730.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04693@8.BIN1#ZZR04693@8.BIN1"</I>
<I>"*","*","ZZR04693@6.BIN1#ZZR04693@6.BIN1"</I>
<I>"*","*","ZZR04693@5.BIN1#ZZR04693@5.BIN1"</I>
<I>"*","*","ZZR04693@7.BIN1#ZZR04693@7.BIN1"</I>
<I>"*","*","ZZR04720#ZZR04720.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04716#ZZR04716.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04718#ZZR04718.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04722#ZZR04722.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04693@2.BIN1#ZZR04693@2.BIN1"</I>
<I>"*","*","ZZR04740#ZZR04740.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04821#ZZR04821"</I>
<I>"*","*","ZZR04822#ZZR04822"</I>
<I>"*","*","ZZR04914#ZZR04914"</I>
<I>"*","*","ZZR04830#ZZR04830.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04834#ZZR04834.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04910#ZZR04910.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04836#ZZR04836.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04854#ZZR04854.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04856#ZZR04856.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04842#ZZR04842.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04844#ZZR04844.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04826#ZZR04826"</I>
<I>"*","*","ZZR04820#ZZR04820"</I>
<I>"*","*","ZZR04860#ZZR04860.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04823@8.BIN1#ZZR04823@8.BIN1"</I>
<I>"*","*","ZZR04823@6.BIN1#ZZR04823@6.BIN1"</I>
<I>"*","*","ZZR04823@5.BIN1#ZZR04823@5.BIN1"</I>
<I>"*","*","ZZR04823@7.BIN1#ZZR04823@7.BIN1"</I>
<I>"*","*","ZZR04850#ZZR04850.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04846#ZZR04846.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04848#ZZR04848.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04852#ZZR04852.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04823@2.BIN1#ZZR04823@2.BIN1"</I>
<I>"*","*","ZZR04870#ZZR04870.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04951#ZZR04951"</I>
<I>"*","*","ZZR04952#ZZR04952"</I>
<I>"*","*","ZZR05044#ZZR05044"</I>
<I>"*","*","ZZR04960#ZZR04960.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04962#ZZR04962.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04972#ZZR04972.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04974#ZZR04974.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04968#ZZR04968.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04970#ZZR04970.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04956#ZZR04956"</I>
<I>"*","*","ZZR04950#ZZR04950"</I>
<I>"*","*","ZZR04990#ZZR04990.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04953@8.BIN1#ZZR04953@8.BIN1"</I>
<I>"*","*","ZZR04953@6.BIN1#ZZR04953@6.BIN1"</I>
<I>"*","*","ZZR04953@5.BIN1#ZZR04953@5.BIN1"</I>
<I>"*","*","ZZR04953@7.BIN1#ZZR04953@7.BIN1"</I>
<I>"*","*","ZZR04980#ZZR04980.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04976#ZZR04976.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04978#ZZR04978.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR04982#ZZR04982.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05081#ZZR05081"</I>
<I>"*","*","ZZR05082#ZZR05082"</I>
<I>"*","*","ZZR05174#ZZR05174"</I>
<I>"*","*","ZZR05090#ZZR05090.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05092#ZZR05092.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05102#ZZR05102.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05104#ZZR05104.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05098#ZZR05098.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05100#ZZR05100.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05086#ZZR05086"</I>
<I>"*","*","ZZR05080#ZZR05080"</I>
<I>"*","*","ZZR05120#ZZR05120.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05083@8.BIN1#ZZR05083@8.BIN1"</I>
<I>"*","*","ZZR05083@6.BIN1#ZZR05083@6.BIN1"</I>
<I>"*","*","ZZR05083@5.BIN1#ZZR05083@5.BIN1"</I>
<I>"*","*","ZZR05083@7.BIN1#ZZR05083@7.BIN1"</I>
<I>"*","*","ZZR05110#ZZR05110.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05106#ZZR05106.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05108#ZZR05108.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05112#ZZR05112.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05211#ZZR05211"</I>
<I>"*","*","ZZR05212#ZZR05212"</I>
<I>"*","*","ZZR05304#ZZR05304"</I>
<I>"*","*","ZZR05220#ZZR05220.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05222#ZZR05222.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05232#ZZR05232.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05234#ZZR05234.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05228#ZZR05228.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05230#ZZR05230.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05216#ZZR05216"</I>
<I>"*","*","ZZR05210#ZZR05210"</I>
<I>"*","*","ZZR05250#ZZR05250.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05213@8.BIN1#ZZR05213@8.BIN1"</I>
<I>"*","*","ZZR05213@6.BIN1#ZZR05213@6.BIN1"</I>
<I>"*","*","ZZR05213@5.BIN1#ZZR05213@5.BIN1"</I>
<I>"*","*","ZZR05213@7.BIN1#ZZR05213@7.BIN1"</I>
<I>"*","*","ZZR05240#ZZR05240.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05236#ZZR05236.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05238#ZZR05238.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05242#ZZR05242.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05341#ZZR05341"</I>
<I>"*","*","ZZR05342#ZZR05342"</I>
<I>"*","*","ZZR05434#ZZR05434"</I>
<I>"*","*","ZZR05350#ZZR05350.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05352#ZZR05352.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05362#ZZR05362.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05364#ZZR05364.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05358#ZZR05358.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05360#ZZR05360.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05346#ZZR05346"</I>
<I>"*","*","ZZR05340#ZZR05340"</I>
<I>"*","*","ZZR05380#ZZR05380.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05343@8.BIN1#ZZR05343@8.BIN1"</I>
<I>"*","*","ZZR05343@6.BIN1#ZZR05343@6.BIN1"</I>
<I>"*","*","ZZR05343@5.BIN1#ZZR05343@5.BIN1"</I>
<I>"*","*","ZZR05343@7.BIN1#ZZR05343@7.BIN1"</I>
<I>"*","*","ZZR05370#ZZR05370.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05366#ZZR05366.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05368#ZZR05368.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05372#ZZR05372.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05471#ZZR05471"</I>
<I>"*","*","ZZR05472#ZZR05472"</I>
<I>"*","*","ZZR05564#ZZR05564"</I>
<I>"*","*","ZZR05480#ZZR05480.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05482#ZZR05482.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05492#ZZR05492.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05494#ZZR05494.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05488#ZZR05488.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05490#ZZR05490.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05476#ZZR05476"</I>
<I>"*","*","ZZR05470#ZZR05470"</I>
<I>"*","*","ZZR05510#ZZR05510.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05473@8.BIN1#ZZR05473@8.BIN1"</I>
<I>"*","*","ZZR05473@6.BIN1#ZZR05473@6.BIN1"</I>
<I>"*","*","ZZR05473@5.BIN1#ZZR05473@5.BIN1"</I>
<I>"*","*","ZZR05473@7.BIN1#ZZR05473@7.BIN1"</I>
<I>"*","*","ZZR05500#ZZR05500.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05496#ZZR05496.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05498#ZZR05498.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05502#ZZR05502.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR05610@0.BIN1#ZZR05610@0.BIN1"</I>
<I>"*","*","ZZR05609@0.BIN1#ZZR05609@0.BIN1"</I>
<I>"*","*","ZZR05610@1.BIN1#ZZR05610@1.BIN1"</I>
<I>"*","*","ZZR05609@1.BIN1#ZZR05609@1.BIN1"</I>
<I>"*","*","ZZR05610@2.BIN1#ZZR05610@2.BIN1"</I>
<I>"*","*","ZZR05609@2.BIN1#ZZR05609@2.BIN1"</I>
<I>"*","*","ZZR05609@3.BIN1#ZZR05609@3.BIN1"</I>
<I>"*","*","ZZR05616#ZZR05616.BIN32"</I>
<I>"*","*","ZZR05606#ZZR05606"</I>
<I>"*","*","ZZR05600#ZZR05600"</I>
<I>"*","*","ZZR05740@0.BIN1#ZZR05740@0.BIN1"</I>
<I>"*","*","ZZR05739@0.BIN1#ZZR05739@0.BIN1"</I>
<I>"*","*","ZZR05740@1.BIN1#ZZR05740@1.BIN1"</I>
<I>"*","*","ZZR05739@1.BIN1#ZZR05739@1.BIN1"</I>
<I>"*","*","ZZR05740@2.BIN1#ZZR05740@2.BIN1"</I>
<I>"*","*","ZZR05739@2.BIN1#ZZR05739@2.BIN1"</I>
<I>"*","*","ZZR05739@3.BIN1#ZZR05739@3.BIN1"</I>
<I>"*","*","ZZR05746#ZZR05746.BIN32"</I>
<I>"*","*","ZZR05736#ZZR05736"</I>
<I>"*","*","ZZR05730#ZZR05730"</I>
<I>"*","*","ZZR05870@0.BIN1#ZZR05870@0.BIN1"</I>
<I>"*","*","ZZR05869@0.BIN1#ZZR05869@0.BIN1"</I>
<I>"*","*","ZZR05870@1.BIN1#ZZR05870@1.BIN1"</I>
<I>"*","*","ZZR05869@1.BIN1#ZZR05869@1.BIN1"</I>
<I>"*","*","ZZR05870@2.BIN1#ZZR05870@2.BIN1"</I>
<I>"*","*","ZZR05869@2.BIN1#ZZR05869@2.BIN1"</I>
<I>"*","*","ZZR05869@3.BIN1#ZZR05869@3.BIN1"</I>
<I>"*","*","ZZR05876#ZZR05876.BIN32"</I>
<I>"*","*","ZZR05866#ZZR05866"</I>
<I>"*","*","ZZR05860#ZZR05860"</I>
<I>"*","*","ZZR06000@0.BIN1#ZZR06000@0.BIN1"</I>
<I>"*","*","ZZR05999@0.BIN1#ZZR05999@0.BIN1"</I>
<I>"*","*","ZZR06000@1.BIN1#ZZR06000@1.BIN1"</I>
<I>"*","*","ZZR05999@1.BIN1#ZZR05999@1.BIN1"</I>
<I>"*","*","ZZR06000@2.BIN1#ZZR06000@2.BIN1"</I>
<I>"*","*","ZZR05999@2.BIN1#ZZR05999@2.BIN1"</I>
<I>"*","*","ZZR05999@3.BIN1#ZZR05999@3.BIN1"</I>
<I>"*","*","ZZR06006#ZZR06006.BIN32"</I>
<I>"*","*","ZZR05996#ZZR05996"</I>
<I>"*","*","ZZR05990#ZZR05990"</I>
<I>"*","*","ZZR06130@0.BIN1#ZZR06130@0.BIN1"</I>
<I>"*","*","ZZR06129@0.BIN1#ZZR06129@0.BIN1"</I>
<I>"*","*","ZZR06130@1.BIN1#ZZR06130@1.BIN1"</I>
<I>"*","*","ZZR06129@1.BIN1#ZZR06129@1.BIN1"</I>
<I>"*","*","ZZR06130@2.BIN1#ZZR06130@2.BIN1"</I>
<I>"*","*","ZZR06129@2.BIN1#ZZR06129@2.BIN1"</I>
<I>"*","*","ZZR06129@3.BIN1#ZZR06129@3.BIN1"</I>
<I>"*","*","ZZR06136#ZZR06136.BIN32"</I>
<I>"*","*","ZZR06126#ZZR06126"</I>
<I>"*","*","ZZR06120#ZZR06120"</I>
<I>"*","*","ZZR06251#ZZR06251"</I>
<I>"*","*","ZZR06252#ZZR06252"</I>
<I>"*","*","ZZR06344#ZZR06344"</I>
<I>"*","*","ZZR06260#ZZR06260.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06264#ZZR06264.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06262#ZZR06262.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06306#ZZR06306.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06302#ZZR06302.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06304#ZZR06304.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06284#ZZR06284.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06286#ZZR06286.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06266#ZZR06266.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06272#ZZR06272.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06274#ZZR06274.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06268#ZZR06268.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06270#ZZR06270.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06256#ZZR06256"</I>
<I>"*","*","ZZR06250#ZZR06250"</I>
<I>"*","*","ZZR06290#ZZR06290.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06253@8.BIN1#ZZR06253@8.BIN1"</I>
<I>"*","*","ZZR06253@6.BIN1#ZZR06253@6.BIN1"</I>
<I>"*","*","ZZR06253@5.BIN1#ZZR06253@5.BIN1"</I>
<I>"*","*","ZZR06253@7.BIN1#ZZR06253@7.BIN1"</I>
<I>"*","*","ZZR06280#ZZR06280.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06276#ZZR06276.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06278#ZZR06278.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06282#ZZR06282.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06253@1.BIN1#ZZR06253@1.BIN1"</I>
<I>"*","*","ZZR06253@0.BIN1#ZZR06253@0.BIN1"</I>
<I>"*","*","ZZR06381#ZZR06381"</I>
<I>"*","*","ZZR06382#ZZR06382"</I>
<I>"*","*","ZZR06474#ZZR06474"</I>
<I>"*","*","ZZR06390#ZZR06390.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06394#ZZR06394.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06392#ZZR06392.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06436#ZZR06436.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06432#ZZR06432.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06434#ZZR06434.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06414#ZZR06414.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06416#ZZR06416.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06396#ZZR06396.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06402#ZZR06402.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06404#ZZR06404.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06398#ZZR06398.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06400#ZZR06400.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06386#ZZR06386"</I>
<I>"*","*","ZZR06380#ZZR06380"</I>
<I>"*","*","ZZR06420#ZZR06420.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06383@8.BIN1#ZZR06383@8.BIN1"</I>
<I>"*","*","ZZR06383@6.BIN1#ZZR06383@6.BIN1"</I>
<I>"*","*","ZZR06383@5.BIN1#ZZR06383@5.BIN1"</I>
<I>"*","*","ZZR06383@7.BIN1#ZZR06383@7.BIN1"</I>
<I>"*","*","ZZR06410#ZZR06410.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06406#ZZR06406.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06408#ZZR06408.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06412#ZZR06412.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06383@1.BIN1#ZZR06383@1.BIN1"</I>
<I>"*","*","ZZR06383@0.BIN1#ZZR06383@0.BIN1"</I>
<I>"*","*","ZZR06511#ZZR06511"</I>
<I>"*","*","ZZR06512#ZZR06512"</I>
<I>"*","*","ZZR06604#ZZR06604"</I>
<I>"*","*","ZZR06520#ZZR06520.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06524#ZZR06524.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06522#ZZR06522.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06566#ZZR06566.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06562#ZZR06562.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06564#ZZR06564.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06544#ZZR06544.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06546#ZZR06546.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06526#ZZR06526.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06532#ZZR06532.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06534#ZZR06534.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06528#ZZR06528.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06530#ZZR06530.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06516#ZZR06516"</I>
<I>"*","*","ZZR06510#ZZR06510"</I>
<I>"*","*","ZZR06550#ZZR06550.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06513@8.BIN1#ZZR06513@8.BIN1"</I>
<I>"*","*","ZZR06513@6.BIN1#ZZR06513@6.BIN1"</I>
<I>"*","*","ZZR06513@5.BIN1#ZZR06513@5.BIN1"</I>
<I>"*","*","ZZR06513@7.BIN1#ZZR06513@7.BIN1"</I>
<I>"*","*","ZZR06540#ZZR06540.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06536#ZZR06536.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06538#ZZR06538.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06542#ZZR06542.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06513@1.BIN1#ZZR06513@1.BIN1"</I>
<I>"*","*","ZZR06513@0.BIN1#ZZR06513@0.BIN1"</I>
<I>"*","*","ZZR06641#ZZR06641"</I>
<I>"*","*","ZZR06642#ZZR06642"</I>
<I>"*","*","ZZR06734#ZZR06734"</I>
<I>"*","*","ZZR06650#ZZR06650.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06654#ZZR06654.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06652#ZZR06652.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06696#ZZR06696.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06692#ZZR06692.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06694#ZZR06694.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06674#ZZR06674.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06676#ZZR06676.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06656#ZZR06656.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06662#ZZR06662.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06664#ZZR06664.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06658#ZZR06658.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06660#ZZR06660.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06646#ZZR06646"</I>
<I>"*","*","ZZR06640#ZZR06640"</I>
<I>"*","*","ZZR06680#ZZR06680.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06643@8.BIN1#ZZR06643@8.BIN1"</I>
<I>"*","*","ZZR06643@6.BIN1#ZZR06643@6.BIN1"</I>
<I>"*","*","ZZR06643@5.BIN1#ZZR06643@5.BIN1"</I>
<I>"*","*","ZZR06643@7.BIN1#ZZR06643@7.BIN1"</I>
<I>"*","*","ZZR06670#ZZR06670.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06666#ZZR06666.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06668#ZZR06668.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06672#ZZR06672.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06643@1.BIN1#ZZR06643@1.BIN1"</I>
<I>"*","*","ZZR06643@0.BIN1#ZZR06643@0.BIN1"</I>
<I>"*","*","ZZR06771#ZZR06771"</I>
<I>"*","*","ZZR06772#ZZR06772"</I>
<I>"*","*","ZZR06864#ZZR06864"</I>
<I>"*","*","ZZR06780#ZZR06780.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06784#ZZR06784.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06782#ZZR06782.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06826#ZZR06826.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06822#ZZR06822.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06824#ZZR06824.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06804#ZZR06804.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06806#ZZR06806.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06786#ZZR06786.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06792#ZZR06792.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06794#ZZR06794.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06788#ZZR06788.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06790#ZZR06790.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06776#ZZR06776"</I>
<I>"*","*","ZZR06770#ZZR06770"</I>
<I>"*","*","ZZR06810#ZZR06810.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06773@8.BIN1#ZZR06773@8.BIN1"</I>
<I>"*","*","ZZR06773@6.BIN1#ZZR06773@6.BIN1"</I>
<I>"*","*","ZZR06773@5.BIN1#ZZR06773@5.BIN1"</I>
<I>"*","*","ZZR06773@7.BIN1#ZZR06773@7.BIN1"</I>
<I>"*","*","ZZR06800#ZZR06800.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06796#ZZR06796.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06798#ZZR06798.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06802#ZZR06802.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06773@1.BIN1#ZZR06773@1.BIN1"</I>
<I>"*","*","ZZR06773@0.BIN1#ZZR06773@0.BIN1"</I>
<I>"*","*","ZZR08331#ZZR08331"</I>
<I>"*","*","ZZR08332#ZZR08332"</I>
<I>"*","*","ZZR08424#ZZR08424"</I>
<I>"*","*","ZZR08340#ZZR08340.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08344#ZZR08344.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08342#ZZR08342.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08386#ZZR08386.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08382#ZZR08382.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08384#ZZR08384.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08364#ZZR08364.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08366#ZZR08366.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08346#ZZR08346.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08352#ZZR08352.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08354#ZZR08354.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08348#ZZR08348.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08350#ZZR08350.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08336#ZZR08336"</I>
<I>"*","*","ZZR08330#ZZR08330"</I>
<I>"*","*","ZZR08370#ZZR08370.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08333@8.BIN1#ZZR08333@8.BIN1"</I>
<I>"*","*","ZZR08333@6.BIN1#ZZR08333@6.BIN1"</I>
<I>"*","*","ZZR08333@5.BIN1#ZZR08333@5.BIN1"</I>
<I>"*","*","ZZR08333@7.BIN1#ZZR08333@7.BIN1"</I>
<I>"*","*","ZZR08360#ZZR08360.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08356#ZZR08356.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08358#ZZR08358.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08362#ZZR08362.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08333@1.BIN1#ZZR08333@1.BIN1"</I>
<I>"*","*","ZZR08333@0.BIN1#ZZR08333@0.BIN1"</I>
<I>"*","*","ZZR06901#ZZR06901"</I>
<I>"*","*","ZZR06902#ZZR06902"</I>
<I>"*","*","ZZR06994#ZZR06994"</I>
<I>"*","*","ZZR06910#ZZR06910.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06914#ZZR06914.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06912#ZZR06912.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06916#ZZR06916.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06952#ZZR06952.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06954#ZZR06954.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06956#ZZR06956.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06934#ZZR06934.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06936#ZZR06936.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06922#ZZR06922.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06924#ZZR06924.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06918#ZZR06918.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06920#ZZR06920.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06906#ZZR06906"</I>
<I>"*","*","ZZR06900#ZZR06900"</I>
<I>"*","*","ZZR06940#ZZR06940.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06903@8.BIN1#ZZR06903@8.BIN1"</I>
<I>"*","*","ZZR06903@6.BIN1#ZZR06903@6.BIN1"</I>
<I>"*","*","ZZR06903@5.BIN1#ZZR06903@5.BIN1"</I>
<I>"*","*","ZZR06903@7.BIN1#ZZR06903@7.BIN1"</I>
<I>"*","*","ZZR06930#ZZR06930.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06926#ZZR06926.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06928#ZZR06928.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06932#ZZR06932.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06903@2.BIN1#ZZR06903@2.BIN1"</I>
<I>"*","*","ZZR06950#ZZR06950.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR06903@1.BIN1#ZZR06903@1.BIN1"</I>
<I>"*","*","ZZR06903@0.BIN1#ZZR06903@0.BIN1"</I>
<I>"*","*","ZZR07031#ZZR07031"</I>
<I>"*","*","ZZR07032#ZZR07032"</I>
<I>"*","*","ZZR07124#ZZR07124"</I>
<I>"*","*","ZZR07040#ZZR07040.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07044#ZZR07044.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07042#ZZR07042.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07046#ZZR07046.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07082#ZZR07082.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07084#ZZR07084.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07086#ZZR07086.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07064#ZZR07064.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07066#ZZR07066.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07052#ZZR07052.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07054#ZZR07054.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07048#ZZR07048.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07050#ZZR07050.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07036#ZZR07036"</I>
<I>"*","*","ZZR07030#ZZR07030"</I>
<I>"*","*","ZZR07070#ZZR07070.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07033@8.BIN1#ZZR07033@8.BIN1"</I>
<I>"*","*","ZZR07033@6.BIN1#ZZR07033@6.BIN1"</I>
<I>"*","*","ZZR07033@5.BIN1#ZZR07033@5.BIN1"</I>
<I>"*","*","ZZR07033@7.BIN1#ZZR07033@7.BIN1"</I>
<I>"*","*","ZZR07060#ZZR07060.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07056#ZZR07056.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07058#ZZR07058.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07062#ZZR07062.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07033@2.BIN1#ZZR07033@2.BIN1"</I>
<I>"*","*","ZZR07080#ZZR07080.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07033@1.BIN1#ZZR07033@1.BIN1"</I>
<I>"*","*","ZZR07033@0.BIN1#ZZR07033@0.BIN1"</I>
<I>"*","*","ZZR07161#ZZR07161"</I>
<I>"*","*","ZZR07162#ZZR07162"</I>
<I>"*","*","ZZR07254#ZZR07254"</I>
<I>"*","*","ZZR07170#ZZR07170.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07174#ZZR07174.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07172#ZZR07172.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07176#ZZR07176.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07212#ZZR07212.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07214#ZZR07214.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07216#ZZR07216.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07194#ZZR07194.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07196#ZZR07196.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07182#ZZR07182.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07184#ZZR07184.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07178#ZZR07178.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07180#ZZR07180.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07166#ZZR07166"</I>
<I>"*","*","ZZR07160#ZZR07160"</I>
<I>"*","*","ZZR07200#ZZR07200.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07163@8.BIN1#ZZR07163@8.BIN1"</I>
<I>"*","*","ZZR07163@6.BIN1#ZZR07163@6.BIN1"</I>
<I>"*","*","ZZR07163@5.BIN1#ZZR07163@5.BIN1"</I>
<I>"*","*","ZZR07163@7.BIN1#ZZR07163@7.BIN1"</I>
<I>"*","*","ZZR07190#ZZR07190.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07186#ZZR07186.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07188#ZZR07188.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07192#ZZR07192.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07163@2.BIN1#ZZR07163@2.BIN1"</I>
<I>"*","*","ZZR07210#ZZR07210.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07163@1.BIN1#ZZR07163@1.BIN1"</I>
<I>"*","*","ZZR07163@0.BIN1#ZZR07163@0.BIN1"</I>
<I>"*","*","ZZR07291#ZZR07291"</I>
<I>"*","*","ZZR07292#ZZR07292"</I>
<I>"*","*","ZZR07384#ZZR07384"</I>
<I>"*","*","ZZR07300#ZZR07300.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07304#ZZR07304.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07302#ZZR07302.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07306#ZZR07306.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07342#ZZR07342.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07344#ZZR07344.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07346#ZZR07346.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07324#ZZR07324.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07326#ZZR07326.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07312#ZZR07312.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07314#ZZR07314.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07308#ZZR07308.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07310#ZZR07310.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07296#ZZR07296"</I>
<I>"*","*","ZZR07290#ZZR07290"</I>
<I>"*","*","ZZR07330#ZZR07330.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07293@8.BIN1#ZZR07293@8.BIN1"</I>
<I>"*","*","ZZR07293@6.BIN1#ZZR07293@6.BIN1"</I>
<I>"*","*","ZZR07293@5.BIN1#ZZR07293@5.BIN1"</I>
<I>"*","*","ZZR07293@7.BIN1#ZZR07293@7.BIN1"</I>
<I>"*","*","ZZR07320#ZZR07320.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07316#ZZR07316.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07318#ZZR07318.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07322#ZZR07322.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07293@2.BIN1#ZZR07293@2.BIN1"</I>
<I>"*","*","ZZR07340#ZZR07340.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07293@1.BIN1#ZZR07293@1.BIN1"</I>
<I>"*","*","ZZR07293@0.BIN1#ZZR07293@0.BIN1"</I>
<I>"*","*","ZZR07421#ZZR07421"</I>
<I>"*","*","ZZR07422#ZZR07422"</I>
<I>"*","*","ZZR07514#ZZR07514"</I>
<I>"*","*","ZZR07430#ZZR07430.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07434#ZZR07434.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07432#ZZR07432.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07436#ZZR07436.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07472#ZZR07472.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07474#ZZR07474.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07476#ZZR07476.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07454#ZZR07454.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07456#ZZR07456.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07442#ZZR07442.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07444#ZZR07444.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07438#ZZR07438.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07440#ZZR07440.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07426#ZZR07426"</I>
<I>"*","*","ZZR07420#ZZR07420"</I>
<I>"*","*","ZZR07460#ZZR07460.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07423@8.BIN1#ZZR07423@8.BIN1"</I>
<I>"*","*","ZZR07423@6.BIN1#ZZR07423@6.BIN1"</I>
<I>"*","*","ZZR07423@5.BIN1#ZZR07423@5.BIN1"</I>
<I>"*","*","ZZR07423@7.BIN1#ZZR07423@7.BIN1"</I>
<I>"*","*","ZZR07450#ZZR07450.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07446#ZZR07446.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07448#ZZR07448.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07452#ZZR07452.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07423@2.BIN1#ZZR07423@2.BIN1"</I>
<I>"*","*","ZZR07470#ZZR07470.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR07423@1.BIN1#ZZR07423@1.BIN1"</I>
<I>"*","*","ZZR07423@0.BIN1#ZZR07423@0.BIN1"</I>
<I>"*","*","ZZR08461#ZZR08461"</I>
<I>"*","*","ZZR08462#ZZR08462"</I>
<I>"*","*","ZZR08554#ZZR08554"</I>
<I>"*","*","ZZR08470#ZZR08470.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08474#ZZR08474.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08472#ZZR08472.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08476#ZZR08476.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08512#ZZR08512.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08514#ZZR08514.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08516#ZZR08516.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08494#ZZR08494.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08496#ZZR08496.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08482#ZZR08482.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08484#ZZR08484.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08478#ZZR08478.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08480#ZZR08480.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08466#ZZR08466"</I>
<I>"*","*","ZZR08460#ZZR08460"</I>
<I>"*","*","ZZR08500#ZZR08500.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08463@8.BIN1#ZZR08463@8.BIN1"</I>
<I>"*","*","ZZR08463@6.BIN1#ZZR08463@6.BIN1"</I>
<I>"*","*","ZZR08463@5.BIN1#ZZR08463@5.BIN1"</I>
<I>"*","*","ZZR08463@7.BIN1#ZZR08463@7.BIN1"</I>
<I>"*","*","ZZR08490#ZZR08490.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08486#ZZR08486.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08488#ZZR08488.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08492#ZZR08492.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08463@2.BIN1#ZZR08463@2.BIN1"</I>
<I>"*","*","ZZR08510#ZZR08510.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08463@1.BIN1#ZZR08463@1.BIN1"</I>
<I>"*","*","ZZR08463@0.BIN1#ZZR08463@0.BIN1"</I>
<I>"*","*","ZZR08591#ZZR08591"</I>
<I>"*","*","ZZR08592#ZZR08592"</I>
<I>"*","*","ZZR08684#ZZR08684"</I>
<I>"*","*","ZZR08600#ZZR08600.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08604#ZZR08604.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08602#ZZR08602.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08606#ZZR08606.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08642#ZZR08642.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08644#ZZR08644.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08646#ZZR08646.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08624#ZZR08624.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08626#ZZR08626.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08612#ZZR08612.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08614#ZZR08614.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08608#ZZR08608.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08610#ZZR08610.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08596#ZZR08596"</I>
<I>"*","*","ZZR08590#ZZR08590"</I>
<I>"*","*","ZZR08630#ZZR08630.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08593@8.BIN1#ZZR08593@8.BIN1"</I>
<I>"*","*","ZZR08593@6.BIN1#ZZR08593@6.BIN1"</I>
<I>"*","*","ZZR08593@5.BIN1#ZZR08593@5.BIN1"</I>
<I>"*","*","ZZR08593@7.BIN1#ZZR08593@7.BIN1"</I>
<I>"*","*","ZZR08620#ZZR08620.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08616#ZZR08616.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08618#ZZR08618.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08622#ZZR08622.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08593@2.BIN1#ZZR08593@2.BIN1"</I>
<I>"*","*","ZZR08640#ZZR08640.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08593@1.BIN1#ZZR08593@1.BIN1"</I>
<I>"*","*","ZZR08593@0.BIN1#ZZR08593@0.BIN1"</I>
<I>"*","*","ZZR08721#ZZR08721"</I>
<I>"*","*","ZZR08722#ZZR08722"</I>
<I>"*","*","ZZR08814#ZZR08814"</I>
<I>"*","*","ZZR08730#ZZR08730.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08734#ZZR08734.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08732#ZZR08732.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08736#ZZR08736.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08772#ZZR08772.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08774#ZZR08774.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08776#ZZR08776.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08754#ZZR08754.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08756#ZZR08756.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08742#ZZR08742.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08744#ZZR08744.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08738#ZZR08738.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08740#ZZR08740.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08726#ZZR08726"</I>
<I>"*","*","ZZR08720#ZZR08720"</I>
<I>"*","*","ZZR08760#ZZR08760.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08723@8.BIN1#ZZR08723@8.BIN1"</I>
<I>"*","*","ZZR08723@6.BIN1#ZZR08723@6.BIN1"</I>
<I>"*","*","ZZR08723@5.BIN1#ZZR08723@5.BIN1"</I>
<I>"*","*","ZZR08723@7.BIN1#ZZR08723@7.BIN1"</I>
<I>"*","*","ZZR08750#ZZR08750.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08746#ZZR08746.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08748#ZZR08748.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08752#ZZR08752.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08723@2.BIN1#ZZR08723@2.BIN1"</I>
<I>"*","*","ZZR08770#ZZR08770.FLT+FIL=DEC:1|0|0"</I>
<I>"*","*","ZZR08723@1.BIN1#ZZR08723@1.BIN1"</I>
<I>"*","*","ZZR08723@0.BIN1#ZZR08723@0.BIN1"</I>
</Driver>
<Network PARAM="">
</Network>
<Structure PARAM="+STRAGETYPE=TYPE2">
<Class PARAM="">
<SYSMAC PARAM="CLASSFOLDER:">
<CJ PARAM="CLASSFOLDER:">
<SI PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass]%cret%IN = {OnDevice}{1},{OffDevice}{0},{default}{0}%cret%OUT = Value%cret%%cret%[AlarmBit2]%cret%IN = !Maintenance &amp;&amp; AlarmEnable%cret%IN = Value%cret%IN = Delay%cret%OUT = Alarm">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel#+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+HOLDVALUE=Y+DEFAULT=(N/A)+TYPE=NUM</I>
</SI>
<SO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Priority2] %cret%IN = !Prohibit%cret%IN = 0%cret%IN = PulseMode%cret%IN = PulseTime%cret%IN = 2%cret%IN = OutputValue%cret%OUT = OutputValue%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>AM_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Label#+HOLDVALUE=Y+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
</SO>
<PVI PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>PVFailure#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PVI>
<SVO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>LR_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Hi#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVLimit_Lo#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>PVFailure#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</SVO>
<MVO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVHi_Device &amp;&amp; Alarm_MVHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVLo_Device &amp;&amp; Alarm_MVLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret%OUT = Alarm_MVHi%cret%OUT = Alarm_MVLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo || Alarm_MVHi || Alarm_MVLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>AM_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVLimit_Lo#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>PVFailure#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</MVO>
<CNT PARAM="CLASSTAG:">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>RunStop#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=9999+TYPE=NUM</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
</CNT>
<PR PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_MVHi_Device &amp;&amp; Alarm_MVHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVLo_Device &amp;&amp; Alarm_MVLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_MVHi%cret%OUT = Alarm_MVLo%cret% %cret%[Bypass] %cret%IN = Alarm_MVHi || Alarm_MVLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>AM_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>LR_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Ratio#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>SVMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>SVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>SVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>SVLimit_Hi#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVLimit_Lo#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVLimit_Lo#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>InBias#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutBias#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>PVFailure#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PR>
<PID PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%IN = DvAlarmDevice &amp;&amp; DvAlarmEnable &amp;&amp; !Maintenance%cret%IN = Alarm_MVHi_Device &amp;&amp; Alarm_MVHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVLo_Device &amp;&amp; Alarm_MVLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret%OUT = DvAlarm%cret%OUT = Alarm_MVHi%cret%OUT = Alarm_MVLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo || DvAlarm || Alarm_MVHi || Alarm_MVLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=SYSMAC.CJ.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>AM_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>LR_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV_Mode#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Hi#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVLimit_Lo#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVPLCMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVPLCMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=115+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-15+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVLimit_Lo#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=320+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-320+TYPE=NUM</I>
<I>DVPLC#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>PVFailure#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Bypass#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PID>
</CJ>
</SYSMAC>
<MELSEC PARAM="CLASSFOLDER:">
<QnPH PARAM="CLASSFOLDER:">
<SI PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = {OnDevice}{1},{OffDevice}{0},{default}{0}%cret%OUT = Value%cret% %cret%[AlarmBit2] %cret%IN = !Maintenance &amp;&amp; AlarmEnable%cret%IN = Value%cret%IN = Delay%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</SI>
<SO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Priority2] %cret%IN = !Prohibit%cret%IN = 0%cret%IN = PulseMode%cret%IN = PulseTime%cret%IN = 2%cret%IN = OutputTrigger%cret%OUT = OutputValue%cret%OUT = OutputValueOn%cret%OUT = OutputValueOff%cret% %cret%[Bypass] %cret%IN = {OnDevice}{1},{OffDevice}{0},{default}{0}%cret%OUT = Value%cret% %cret%[Bypass] %cret%IN = Alarm_Congestion_Device &amp;&amp; Alarm_Congestion_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Trip_Device &amp;&amp; Alarm_Trip_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_Congestion%cret%OUT = Alarm_Trip%cret% %cret%[Bypass] %cret%IN = Alarm_Congestion || Alarm_Trip%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Label#+HOLDVALUE=Y+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</SO>
<PVI PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PVI>
<SVO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%IN = DvAlarmDevice &amp;&amp; DvAlarmEnable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret%OUT = DvAlarm%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo || DvAlarm%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</SVO>
<MVO PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</MVO>
<CNT PARAM="CLASSTAG:">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
</CNT>
<PR PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVHi_Device &amp;&amp; Alarm_MVHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVLo_Device &amp;&amp; Alarm_MVLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret%OUT = Alarm_MVHi%cret%OUT = Alarm_MVLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo || Alarm_MVHi || Alarm_MVLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PR>
<PID PARAM="CLASSTAG:+FUNCTIONBLOCK=[Bypass] %cret%IN = Alarm_HiHi_Device &amp;&amp; Alarm_HiHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Hi_Device &amp;&amp; Alarm_Hi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_Lo_Device &amp;&amp; Alarm_Lo_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_LoLo_Device &amp;&amp; Alarm_LoLo_Enable &amp;&amp; !Maintenance%cret%IN = DvAlarmDevice &amp;&amp; DvAlarmEnable &amp;&amp; !Maintenance%cret%IN = Alarm_MVHi_Device &amp;&amp; Alarm_MVHi_Enable &amp;&amp; !Maintenance%cret%IN = Alarm_MVLo_Device &amp;&amp; Alarm_MVLo_Enable &amp;&amp; !Maintenance%cret%OUT = Alarm_HiHi%cret%OUT = Alarm_Hi%cret%OUT = Alarm_Lo%cret%OUT = Alarm_LoLo%cret%OUT = DvAlarm%cret%OUT = Alarm_MVHi%cret%OUT = Alarm_MVLo%cret% %cret%[Bypass] %cret%IN = Alarm_HiHi || Alarm_Hi || Alarm_Lo || Alarm_LoLo || DvAlarm || Alarm_MVHi || Alarm_MVLo%cret%OUT = Alarm%cret%">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=110+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=-10+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM</I>
<I>GraphicId#+HOLDVALUE=Y+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</PID>
</QnPH>
</MELSEC>
</Class>
<Instance PARAM="">
<CNT PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.CNT">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=CNT-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=CNT-101(カウンタ)+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05610@0.BIN1;OUT:PLC01.F01.ZZR05609@0.BIN1</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05610@1.BIN1;OUT:PLC01.F01.ZZR05609@1.BIN1</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05610@2.BIN1;OUT:PLC01.F01.ZZR05609@2.BIN1</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL+BIND=OUT:PLC01.F01.ZZR05609@3.BIN1</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05616</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=cnt+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05606</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05600)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=CNT+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=CNTｺﾒﾝﾄ+TYPE=STR</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.CNT">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=CNT-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=CNT-102(カウンタ)+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05740@0.BIN1;OUT:PLC01.F01.ZZR05739@0.BIN1</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05740@1.BIN1;OUT:PLC01.F01.ZZR05739@1.BIN1</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05740@2.BIN1;OUT:PLC01.F01.ZZR05739@2.BIN1</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL+BIND=OUT:PLC01.F01.ZZR05739@3.BIN1</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05746</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=cnt+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05736</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05730)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=CNT+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=CNTｺﾒﾝﾄ+TYPE=STR</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.CNT">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=CNT-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=CNT-103(カウンタ)+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05870@0.BIN1;OUT:PLC01.F01.ZZR05869@0.BIN1</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05870@1.BIN1;OUT:PLC01.F01.ZZR05869@1.BIN1</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR05870@2.BIN1;OUT:PLC01.F01.ZZR05869@2.BIN1</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL+BIND=OUT:PLC01.F01.ZZR05869@3.BIN1</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05876</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=cnt+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05866</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05860)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=CNT+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=CNTｺﾒﾝﾄ+TYPE=STR</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.CNT">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=CNT-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=CNT-104(カウンタ)+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06000@0.BIN1;OUT:PLC01.F01.ZZR05999@0.BIN1</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06000@1.BIN1;OUT:PLC01.F01.ZZR05999@1.BIN1</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06000@2.BIN1;OUT:PLC01.F01.ZZR05999@2.BIN1</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL+BIND=OUT:PLC01.F01.ZZR05999@3.BIN1</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06006</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=cnt+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05996</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05990)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=CNT+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=CNTｺﾒﾝﾄ+TYPE=STR</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.CNT">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.CNT+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=CNT-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=CNT-105(カウンタ)+TYPE=STR</I>
<I>Run#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06130@0.BIN1;OUT:PLC01.F01.ZZR06129@0.BIN1</I>
<I>Stop#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06130@1.BIN1;OUT:PLC01.F01.ZZR06129@1.BIN1</I>
<I>Reset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06130@2.BIN1;OUT:PLC01.F01.ZZR06129@2.BIN1</I>
<I>Reset_Start#+DEFAULT=(N/A)+TYPE=BOOL+BIND=OUT:PLC01.F01.ZZR06129@3.BIN1</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06136</I>
<I>Scale#+HOLDVALUE=Y+DEFAULT=1+TYPE=STR</I>
<I>Max#+HOLDVALUE=Y+DEFAULT=99999999+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=cnt+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06126</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06120)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=CNT+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=CNTｺﾒﾝﾄ+TYPE=STR</I>
</105>
</CNT>
<MVO PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.MVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=MVO-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=MVO-101(MV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04951</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04952</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05044</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04960</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04962</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04972</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04974</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04968</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04970</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04956</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04950)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=MV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=MV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04990</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04953@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04953@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04953@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04953@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04980</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04976</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04978</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04982</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=MVO-101(MV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=MVO-101(MV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=MVO-101(MV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=MVO-101(MV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.MVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=MVO-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=MVO-102(MV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05081</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05082</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05174</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05090</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05092</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05102</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05104</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05098</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05100</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05086</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05080)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=MV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=MV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05120</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05083@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05083@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05083@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05083@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05110</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05106</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05108</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05112</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=MVO-102(MV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=MVO-102(MV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=MVO-102(MV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=MVO-102(MV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.MVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=MVO-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=MVO-103(MV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05211</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05212</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05304</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05220</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05222</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05232</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05234</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05228</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05230</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05216</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05210)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=MV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=MV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05250</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05213@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05213@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05213@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05213@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05240</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05236</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05238</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05242</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=MVO-103(MV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=MVO-103(MV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=MVO-103(MV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=MVO-103(MV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.MVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=MVO-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=MVO-104(MV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05341</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05342</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05434</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05350</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05352</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05362</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05364</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05358</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05360</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05346</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05340)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=MV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=MV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05380</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05343@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05343@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05343@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05343@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05370</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05366</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05368</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05372</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=MVO-104(MV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=MVO-104(MV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=MVO-104(MV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=MVO-104(MV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.MVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.MVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=MVO-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=MVO-105(MV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05471</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05472</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05564</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05480</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05482</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05492</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05494</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05488</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05490</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05476</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR05470)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=MV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=MV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05510</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05473@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05473@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05473@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR05473@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05500</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05496</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05498</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR05502</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=MVO-105(MV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=MVO-105(MV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=MVO-105(MV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=MVO-105(MV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</MVO>
<PID PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PID-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06901</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06902</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06994</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06910</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06914</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06912</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR06916)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06952</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06954</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06956</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06934</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06936</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06922</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06924</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06918</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06920</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06906</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06900)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=基本PIDｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06940</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06930</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06926</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06928</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06932</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR06903@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06950</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06903@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06918</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06920</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PID-101(基本PID)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PID-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07031</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07032</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07124</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07040</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07044</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07042</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR07046)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07082</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07084</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07086</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07064</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07066</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07052</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07054</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07048</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07050</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07036</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07030)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=基本PIDｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07070</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07060</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07056</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07058</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07062</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR07033@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07080</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07033@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07048</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07050</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PID-102(基本PID)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PID-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07161</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07162</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07254</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07170</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07174</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07172</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR07176)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07212</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07214</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07216</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07194</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07196</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07182</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07184</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07178</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07180</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07166</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07160)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=基本PIDｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07200</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07190</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07186</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07188</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07192</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR07163@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07210</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07163@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07178</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07180</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PID-103(基本PID)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PID-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07291</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07292</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07384</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07300</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07304</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07302</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR07306)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07342</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07344</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07346</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07324</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07326</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07312</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07314</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07308</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07310</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07296</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07290)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=基本PIDｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07330</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07320</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07316</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07318</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07322</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR07293@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07340</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07293@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07308</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07310</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PID-104(基本PID)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PID-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07421</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07422</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07514</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07430</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07434</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07432</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR07436)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07472</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07474</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07476</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07454</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07456</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07442</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07444</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07438</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07440</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07426</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07420)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=基本PIDｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07460</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07450</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07446</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07448</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07452</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR07423@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07470</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07423@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07438</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07440</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PID-105(基本PID)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</PID>
<TIC PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=TIC-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=炉内温度制御+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08461</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08462</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08554</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08470</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08474</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08472</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR08476)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08512</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08514</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08516</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08494</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08496</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08482</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08484</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=500+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08478</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08480</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08466</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08460)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=炉内温度制御+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08500</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08490</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08486</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08488</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08492</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=炉内温度制御_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=炉内温度制御_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=炉内温度制御_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=炉内温度制御_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR08463@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08510</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=炉内温度制御_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08463@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08478</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08480</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=炉内温度制御_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=炉内温度制御_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
</TIC>
<FIC PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=FIC-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08591</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08592</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08684</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08600</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08604</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08602</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR08606)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08642</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08644</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08646</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08624</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08626</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08612</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08614</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08608</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08610</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=m3/h+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08596</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08590)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08630</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08620</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08616</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08618</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08622</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR08593@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08640</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08593@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08608</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08610</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量制御_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
<2001 PARAM="+CLASS=MELSEC.QnPH.PID">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PID+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=FIC-2001+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=空気流量制御+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08721</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08722</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08814</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08730</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08734</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08732</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR08736)</I>
<I>P#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08772</I>
<I>I#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08774</I>
<I>D#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08776</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08754</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08756</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08742</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08744</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08738</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08740</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=m3/h+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08726</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08720)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=基本PID+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=空気流量制御+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08760</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08750</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08746</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08748</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08752</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=空気流量制御_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=空気流量制御_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=空気流量制御_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=空気流量制御_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR08723@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08770</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=空気流量制御_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08723@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08738</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08740</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=空気流量制御_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=空気流量制御_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2001>
</FIC>
<PR PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PR-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06251</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06252</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06344</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06260</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06264</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06262</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06306</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06302</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06304</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06284</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06286</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06272</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06274</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06268</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06270</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06266</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06256</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06250)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=PRｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06290</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06280</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06276</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06278</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06282</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06253@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06268</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06270</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PR-101(比率設定)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PR-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06381</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06382</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06474</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06390</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06394</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06392</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06436</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06432</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06434</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06414</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06416</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06402</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06404</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06398</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06400</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06396</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06386</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06380)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=PRｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06420</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06410</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06406</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06408</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06412</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06383@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06398</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06400</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PR-102(比率設定)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PR-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06511</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06512</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06604</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06520</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06524</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06522</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06566</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06562</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06564</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06544</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06546</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06532</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06534</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06528</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06530</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06526</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06516</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06510)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=PRｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06550</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06540</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06536</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06538</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06542</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06513@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06528</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06530</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PR-103(比率設定)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PR-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06641</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06642</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06734</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06650</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06654</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06652</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06696</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06692</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06694</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06674</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06676</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06662</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06664</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06658</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06660</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06656</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06646</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06640)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=PRｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06680</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06670</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06666</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06668</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06672</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06643@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06658</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06660</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PR-104(比率設定)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PR-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06771</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06772</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06864</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06780</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06784</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06782</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06826</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06822</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06824</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06804</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06806</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06792</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06794</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06788</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06790</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06786</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06776</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR06770)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=PRｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06810</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06800</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06796</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06798</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06802</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR06773@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06788</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR06790</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=PR-105(比率設定)_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</PR>
<R PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.PR">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PR+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=R-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=空気比率+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08331</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08332</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08424</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08340</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08344</I>
<I>MV#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08342</I>
<I>RN#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08386</I>
<I>SVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08382</I>
<I>SVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08384</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08364</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08366</I>
<I>SVTrendMax#+HOLDVALUE=Y+DEFAULT=20+TYPE=NUM</I>
<I>SVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08352</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08354</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=20+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>MVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08348</I>
<I>MVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08350</I>
<I>MVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>MVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>Bias#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08346</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=%+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08336</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08330)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=PR+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=空気比率+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08370</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08360</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08356</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08358</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08362</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=空気比率_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=空気比率_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=空気比率_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=空気比率_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>Alarm_MVHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_MVHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_MVHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@1.BIN1</I>
<I>Alarm_MVLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08333@0.BIN1</I>
<I>Limit_MVHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08348</I>
<I>Limit_MVLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08350</I>
<I>AlarmMessage_MVHi#+HOLDVALUE=Y+DEFAULT=空気比率_MV上限警報+TYPE=STR</I>
<I>AlarmMessage_MVLo#+HOLDVALUE=Y+DEFAULT=空気比率_MV下限警報+TYPE=STR</I>
<I>AlarmLevel_MVHi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_MVLo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_MVHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_MVLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
</R>
<PVI PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PVI-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PVI-101(数値指示)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03660</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03672</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03674</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03656</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03650)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=数値指示ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03690</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03653@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03653@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03653@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03653@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03680</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03676</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03678</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03682</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PVI-101(数値指示)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PVI-101(数値指示)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PVI-101(数値指示)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PVI-101(数値指示)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PVI-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PVI-102(数値指示)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03790</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03802</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03804</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03786</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03780)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=数値指示ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03820</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03783@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03783@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03783@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03783@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03810</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03806</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03808</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03812</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PVI-102(数値指示)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PVI-102(数値指示)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PVI-102(数値指示)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PVI-102(数値指示)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PVI-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PVI-103(数値指示)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03920</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03932</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03934</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03916</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03910)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=数値指示ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03950</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03913@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03913@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03913@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03913@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03940</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03936</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03938</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03942</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PVI-103(数値指示)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PVI-103(数値指示)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PVI-103(数値指示)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PVI-103(数値指示)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PVI-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PVI-104(数値指示)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04050</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04062</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04064</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04046</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04040)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=数値指示ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04080</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04043@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04043@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04043@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04043@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04070</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04066</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04068</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04072</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PVI-104(数値指示)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PVI-104(数値指示)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PVI-104(数値指示)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PVI-104(数値指示)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=PVI-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=PVI-105(数値指示)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04180</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04192</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04194</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04176</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04170)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=数値指示ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04210</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04173@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04173@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04173@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04173@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04200</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04196</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04198</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04202</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=PVI-105(数値指示)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=PVI-105(数値指示)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=PVI-105(数値指示)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=PVI-105(数値指示)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</PVI>
<TI PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=TI-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07820</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07832</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07834</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=500+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07816</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07810)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07850</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07813@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07813@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07813@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07813@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07840</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07836</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07838</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07842</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(IN)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
<2001 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=TI-2001+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07950</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07962</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07964</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=500+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07946</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07940)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07980</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07943@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07943@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07943@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07943@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07970</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07966</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07968</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07972</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=炉内温度ｾﾝｻ(OUT)_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2001>
</TI>
<FM PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=FM-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08080</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08092</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08094</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=m3/h+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08076</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08070)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08110</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08073@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08073@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08073@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08073@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08100</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08096</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08098</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08102</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=燃焼ｶﾞｽ流量_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
<2001 PARAM="+CLASS=MELSEC.QnPH.PVI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.PVI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=FM-2001+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=空気流量+TYPE=STR</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08210</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08222</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08224</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=100+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=m3/h+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08206</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR08200)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=数値指示+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=空気流量+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08240</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08203@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08203@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08203@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR08203@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08230</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08226</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08228</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR08232</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=空気流量_上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=空気流量_上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=空気流量_下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=空気流量_下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
</2001>
</FM>
<SI PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-101(状態)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02001</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02002</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02003)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=状態+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=状態ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-101(状態)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-102(状態)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02011</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02012</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02013)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=状態+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=状態ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-102(状態)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-103(状態)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02021</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02022</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02023)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=状態+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=状態ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-103(状態)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-104(状態)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02031</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02032</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02033)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=状態+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=状態ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-104(状態)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-105(状態)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02041</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02042</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02043)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=状態+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=状態ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-105(状態)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
<106 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-106+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-106(警報)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:正常,1:異常+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02051</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02052</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02053)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=警報+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=警報ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-106(警報)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</106>
<107 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-107+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-107(警報)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:正常,1:異常+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02061</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02062</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02063)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=警報+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=警報ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-107(警報)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</107>
<108 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-108+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-108(警報)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:正常,1:異常+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02071</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02072</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02073)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=警報+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=警報ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-108(警報)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</108>
<109 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-109+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-109(警報)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:正常,1:異常+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02081</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02082</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02083)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=警報+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=警報ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-109(警報)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</109>
<110 PARAM="+CLASS=MELSEC.QnPH.SI">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SI+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SI-110+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SI-110(警報)+TYPE=STR</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:正常,1:異常+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02091</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.M02092</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.M02093)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=警報+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=警報ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Delay#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>AlarmEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>AlarmMessage#+HOLDVALUE=Y+DEFAULT=SI-110(警報)_警報+TYPE=STR</I>
<I>AlarmLevel#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus#+DEFAULT=(N/A)+TYPE=NUM</I>
</110>
</SI>
<SO PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SO-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SO-101(発停)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03001</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03002</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03009</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03010@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03010@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03009@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03009@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03006</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR03009@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03000)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=発停ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03003@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03003@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=SO-101(発停)_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=SO-101(発停)_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SO-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SO-102(発停)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03131</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03132</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03139</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03140@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03140@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03139@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03139@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03136</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR03139@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03130)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=発停ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03133@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03133@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=SO-102(発停)_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=SO-102(発停)_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SO-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SO-103(発停)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03261</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03262</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03269</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03270@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03270@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03269@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03269@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03266</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR03269@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03260)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=発停ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03263@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03263@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=SO-103(発停)_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=SO-103(発停)_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SO-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SO-104(発停)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03391</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03392</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03399</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03400@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03400@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03399@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03399@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03396</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR03399@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03390)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=発停ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03393@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03393@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=SO-104(発停)_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=SO-104(発停)_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SO-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SO-105(発停)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03521</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR03522</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03529</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:OFF,1:ON+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03530@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03530@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03529@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR03529@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03526</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR03529@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR03520)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=発停ｺﾒﾝﾄ+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03523@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR03523@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=SO-105(発停)_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=SO-105(発停)_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</SO>
<SB PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SB-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=起動_加熱炉+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07551</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07552</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07559</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:停止,1:起動+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07560@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07560@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR07559@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR07559@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07556</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR07559@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07550)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=加熱炉起動+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07553@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07553@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=起動_加熱炉_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=起動_加熱炉_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
</SB>
<SF PARAM="INSTANCEFOLDER:">
<2000 PARAM="+CLASS=MELSEC.QnPH.SO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SF-2000+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=起動_加熱炉ﾌｧﾝ+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07681</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR07682</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07689</I>
<I>Label#+HOLDVALUE=Y+DEFAULT=0:停止,1:起動+TYPE=STR</I>
<I>Value#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OnDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07690@0.BIN1</I>
<I>OffDevice#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07690@2.BIN1</I>
<I>OutputTrigger#+HOLDVALUE=Y+TYPE=STR</I>
<I>OutputValue#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>OutputValueOn#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR07689@0.BIN1</I>
<I>OutputValueOff#+DEFAULT=(N/A)+TYPE=NUM+BIND=OUT:PLC01.F01.ZZR07689@2.BIN1</I>
<I>PulseMode#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>PulseTime#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07686</I>
<I>CongestionReset#+DEFAULT=(N/A)+TYPE=BOOL+BIND=INOUT:PLC01.F01.ZZR07689@5.BIN1</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR07680)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=GraphicScreen_Sample+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=発停+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=加熱炉ﾌｧﾝ起動+TYPE=STR</I>
<I>EventEnable#+HOLDVALUE=Y+DEFAULT=True+TYPE=BOOL</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Alarm_Congestion_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Trip_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Congestion#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Trip#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Congestion_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07683@0.BIN1</I>
<I>Alarm_Trip_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR07683@1.BIN1</I>
<I>AlarmMessage_Congestion#+HOLDVALUE=Y+DEFAULT=起動_加熱炉ﾌｧﾝ_渋滞アラーム警報+TYPE=STR</I>
<I>AlarmMessage_Trip#+HOLDVALUE=Y+DEFAULT=起動_加熱炉ﾌｧﾝ_トリップアラーム警報+TYPE=STR</I>
<I>AlarmLevel_Congestion#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Trip#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_Congestion#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Trip#+DEFAULT=(N/A)+TYPE=NUM</I>
</2000>
</SF>
<SVO PARAM="INSTANCEFOLDER:">
<101 PARAM="+CLASS=MELSEC.QnPH.SVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SVO-101+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04301</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04302</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04394</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04310</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04314;OUT:PLC01.F01.ZZR04390</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR04316)</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04334</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04336</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04322</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04324</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04306</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04300)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=SV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=SV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04340</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04303@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04303@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04303@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04303@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04330</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04326</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04328</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04332</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR04303@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04350</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=SVO-101(SV設定)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</101>
<102 PARAM="+CLASS=MELSEC.QnPH.SVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SVO-102+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04431</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04432</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04524</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04440</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04444;OUT:PLC01.F01.ZZR04520</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR04446)</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04464</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04466</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04452</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04454</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04436</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04430)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=SV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=SV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04470</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04433@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04433@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04433@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04433@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04460</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04456</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04458</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04462</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR04433@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04480</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=SVO-102(SV設定)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</102>
<103 PARAM="+CLASS=MELSEC.QnPH.SVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SVO-103+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04561</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04562</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04654</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04570</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04574;OUT:PLC01.F01.ZZR04650</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR04576)</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04594</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04596</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04582</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04584</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04566</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04560)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=SV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=SV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04600</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04563@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04563@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04563@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04563@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04590</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04586</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04588</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04592</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR04563@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04610</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=SVO-103(SV設定)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</103>
<104 PARAM="+CLASS=MELSEC.QnPH.SVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SVO-104+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04691</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04692</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04784</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04700</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04704;OUT:PLC01.F01.ZZR04780</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR04706)</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04724</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04726</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04712</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04714</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04696</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04690)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=SV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=SV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04730</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04693@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04693@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04693@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04693@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04720</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04716</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04718</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04722</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR04693@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04740</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=SVO-104(SV設定)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</104>
<105 PARAM="+CLASS=MELSEC.QnPH.SVO">
<I>ClassId#+HOLDVALUE=Y+DEFAULT=MELSEC.QnPH.SVO+TYPE=STR</I>
<I>Code#+HOLDVALUE=Y+DEFAULT=SVO-105+TYPE=STR</I>
<I>Name#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)+TYPE=STR</I>
<I>Control_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04821</I>
<I>Control_Prohibit#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04822</I>
<I>IO_Mode#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04914</I>
<I>PV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04830</I>
<I>SV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04834;OUT:PLC01.F01.ZZR04910</I>
<I>DV#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:Math.Abs(PLC01.F01.ZZR04836)</I>
<I>SVLimit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04854</I>
<I>SVLimit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04856</I>
<I>PVMax#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04842</I>
<I>PVMin#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04844</I>
<I>PVTrendMax#+HOLDVALUE=Y+DEFAULT=300+TYPE=NUM</I>
<I>PVTrendMin#+HOLDVALUE=Y+DEFAULT=0+TYPE=NUM</I>
<I>PVMajorDivisions#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>PVMinorDivisions#+HOLDVALUE=Y+DEFAULT=5+TYPE=NUM</I>
<I>Units#+HOLDVALUE=Y+DEFAULT=℃+TYPE=STR</I>
<I>DecimalPlace#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>NoteMultiNo#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04826</I>
<I>Prohibit#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Reliability#+DEFAULT=2+TYPE=NUM+BIND=CQuality(PLC01.F01.ZZR04820)</I>
<I>GraphicId#+HOLDVALUE=Y+DEFAULT=CORE_FacePlate+TYPE=STR</I>
<I>Filter#+HOLDVALUE=Y+DEFAULT=SV設定+TYPE=STR</I>
<I>Comment#+HOLDVALUE=Y+DEFAULT=SV設定ｺﾒﾝﾄ+TYPE=STR</I>
<I>Alarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Maintenance#+HOLDVALUE=Y+DEFAULT=FALSE+TYPE=BOOL</I>
<I>Deadband#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04860</I>
<I>Alarm_HiHi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Hi_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_Lo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_LoLo_Enable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>Alarm_HiHi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Hi#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_Lo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_LoLo#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>Alarm_HiHi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04823@8.BIN1</I>
<I>Alarm_Hi_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04823@6.BIN1</I>
<I>Alarm_Lo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04823@5.BIN1</I>
<I>Alarm_LoLo_Device#+DEFAULT=(N/A)+TYPE=NUM+BIND=IN:PLC01.F01.ZZR04823@7.BIN1</I>
<I>Limit_HiHi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04850</I>
<I>Limit_Hi#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04846</I>
<I>Limit_Lo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04848</I>
<I>Limit_LoLo#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04852</I>
<I>AlarmMessage_HiHi#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)_PV上上限警報+TYPE=STR</I>
<I>AlarmMessage_Hi#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)_PV上限警報+TYPE=STR</I>
<I>AlarmMessage_Lo#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)_PV下限警報+TYPE=STR</I>
<I>AlarmMessage_LoLo#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)_PV下下限警報+TYPE=STR</I>
<I>AlarmLevel_HiHi#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmLevel_Hi#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_Lo#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmLevel_LoLo#+HOLDVALUE=Y+DEFAULT=2+TYPE=NUM</I>
<I>AlarmStatus_HiHi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Hi#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_Lo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>AlarmStatus_LoLo#+DEFAULT=(N/A)+TYPE=NUM</I>
<I>DvAlarmEnable#+HOLDVALUE=Y+DEFAULT=False+TYPE=BOOL</I>
<I>DvAlarm#+DEFAULT=(N/A)+TYPE=BOOL</I>
<I>DvAlarmDevice#+DEFAULT=(N/A)+TYPE=BOOL+BIND=IN:PLC01.F01.ZZR04823@2.BIN1</I>
<I>DvAlarmSet#+DEFAULT=(N/A)+TYPE=NUM+BIND=INOUT:PLC01.F01.ZZR04870</I>
<I>AlarmMessage_Dv#+HOLDVALUE=Y+DEFAULT=SVO-105(SV設定)_偏差警報+TYPE=STR</I>
<I>AlarmLevel_Dv#+HOLDVALUE=Y+DEFAULT=1+TYPE=NUM</I>
<I>AlarmStatus_Dv#+DEFAULT=(N/A)+TYPE=NUM</I>
</105>
</SVO>
</Instance>
</Structure>
</Tag>
<Event PARAM="">
<I>Alarm_Event#INTERVAL:+CATEGORY=Timer+ACTION=Alarm;Event</I>
<I>Summary#DATE:+HOUR=-1+MIN=-1+SEC=-1+CATEGORY=Timer+ACTION=Summary</I>
<I>PrintReport_Day#TAG:+TAG=SYS.REPORT.PRINTDAY+COND=E|1|+ENABLE=N+ACTION=Summary#PRINTREPORT(reportmaster.csv,DAY,DAY-1D,DAY,-1,-1,,F,0,F,1)</I>
<I>PrintReport_Month#TAG:+TAG=SYS.REPORT.PRINTMONTH+COND=E|1|+ENABLE=N+ACTION=Summary#PRINTREPORT(reportmaster.csv,MONTH,MONTH-1MO,MONTH,-1,-1,,F,0,F,1)</I>
<I>PrintReport_Year#TAG:+TAG=SYS.REPORT.PRINTYEAR+COND=E|1|+ENABLE=N+ACTION=Summary#PRINTREPORT(reportmaster.csv,YEAR,YEAR-1Y,YEAR,-1,-1,,F,0,F,1)</I>
<I>Script_Demo#INTERVAL:+CATEGORY=Timer+ACTION=Script.TagVirtual;Script.TagCalcDemo</I>
</Event>
<Action PARAM="">
<CfgFServer PARAM="FILESERVER:+FOLDER=server\config+FOLDERSUB=X:\server\config+FTPSERVER=+FTPUSERNAME=+FTPPASSWORD=">
</CfgFServer>
<CfgDServer PARAM="FILESERVER:+FOLDER=server_data\config+FOLDERSUB=X:\server_data\config+FTPSERVER=+FTPUSERNAME=+FTPPASSWORD=">
</CfgDServer>
<Alarm PARAM="ALARMCSV:+MASTERFILE=server\config\alarm_master.csv+MASTERTYPE=1+TABLEMASTER=0,[DATE];1,[TYPE];2,[ALARMID];3,[ACK];4,[RECOVER];5,[CONDID];6,[CM0];7,[CM1:TAG];8,[CM2:TAG];9,[CM3:TAG];10,[CM4:TAG];11,[CM5];12,[CM6];13,[CM7:TAG];14,[CM8];15,[CM9:TAG];16,[CM10];17,[CM11]+ALARMFOLDER=server_data\alarm+ALARMFOLDERSUB=X:\server_data\alarm+MAINTENANCE=Y+HOLDDAYS=366+MAILLOGINTYPE=NONE+STATEMONITOR=SYS.ALM.ALL, COMMON, notrecover,[CM3] != 0%cret%SYS.ALM.ALL_NOTACK, COMMON_NOTACK, notack,[CM3] != 0%cret%SYS.ALM.ALL_NOTRECOVER, COMMON_NOTRECOVER, notrecover,[CM3] != 0%cret%SYS.ALM.ALL_NOTACK_OR_NOTRECOVER, COMMON_NOTACK_OR_NOTRECOVER, notack_or_notrecover,[CM3] != 0%cret%SYS.ALM.LIGHT, LIGHT, notrecover,[CM3] == 1%cret%SYS.ALM.LIGHT_NOTACK, LIGHT_NOTACK, notack,[CM3] == 1%cret%SYS.ALM.LIGHT_NOTRECOVER, LIGHT_NOTRECOVER, notrecover,[CM3] == 1%cret%SYS.ALM.LIGHT_NOTACK_OR_NOTRECOVER, LIGHT_NOTACK_OR_NOTRECOVER, notack_or_notrecover,[CM3] == 1%cret%SYS.ALM.HEAVY, HEAVY, notrecover,[CM3] == 2%cret%SYS.ALM.HEAVY_NOTACK, HEAVY_NOTACK, notack,[CM3] == 2%cret%SYS.ALM.HEAVY_NOTRECOVER, HEAVY_NOTRECOVER, notrecover,[CM3] == 2%cret%SYS.ALM.HEAVY_NOTACK_OR_NOTRECOVER, HEAVY_NOTACK_OR_NOTRECOVER, notack_or_notrecover,[CM3] == 2%cret%">
</Alarm>
<Event PARAM="ALARMCSV:+MASTERFILE=server\config\event_master.csv+MASTERTYPE=1+TABLEMASTER=0,[DATE];1,[TYPE];2,[ALARMID];3,[ACK];4,[RECOVER];5,[CONDID];6,[CM0];7,[CM1:TAG];8,[CM2:TAG];9,[CM3:TAG];10,[CM4:TAG];11,[CM5];12,[CM6];13,[CM7:TAG];14,[CM8];15,[CM9];16,[CM10]+ALARMFOLDER=server_data\event+ALARMFOLDERSUB=X:\server_data\event+MAINTENANCE=Y+HOLDDAYS=366+MAILLOGINTYPE=NONE">
</Event>
<Summary PARAM="SUMMARYCSV:+SUMMARYMASTERFILE=server\summary\master.txt+SUMMARYFOLDER=server_data\summary+SUMMARYFOLDERSUB=X:\server_data\summary">
</Summary>
<Script PARAM="FOLDER:">
<TagVirtual PARAM="BRIDGE:">
<I>PLC01#+SOURCE=PLC01!Virtual+DESTINATION=SYS.MODE.PLC01_VIRTUAL</I>
</TagVirtual>
<TagCalcDemo PARAM="SCRIPTSERVER:+FILE=server\script\tagcalc_demo.txt">
</TagCalcDemo>
</Script>
</Action>
<View PARAM="">
<Main PARAM="">
</Main>
<Option PARAM="">
<Output01 PARAM="Output:+SOURCEIDS=System,Tag,Driver,View,Action,Redundancy,Script2+FILENAME=server_data\log\outputlog\.txt+SAVEFILE=Y+SAVEDAYS=365+MAXDISPLAY=5000">
</Output01>
</Option>
</View>
<Interface PARAM="">
<I>OPC#</I>
<I>DDE#</I>
<I>IPLink#+PORT=6021</I>
<I>Panel#+SAVEUSERINFOTYPE=TYPE1+USER=user,pass,0,N+LOGINPROJECT=project,build\project\client\PA-Client.xml,,Y</I>
<I>Redundancy#</I>
</Interface>
</ROOT>